I-beam optimization for a test fixture. Steel (AISI 1005) cantilever beam with lightening holes in the web. Goal: minimize mass from **1,133.01 kg** baseline while meeting displacement (≤ 10 mm) and stress (≤ 130 MPa) constraints.
| G1 | Beam length and support conditions | 5,000 mm cantilever (left fixed, right free) | Gen 002 |
| G2 | Loading definition | 10,000 kgf point load, downward (−Y), at free end | Gen 002 |
| G8 | Mesh type and density | CQUAD4 thin shell, 33.7 mm element size (67.4/2) | Gen 002 |
### 🟡 PARTIALLY RESOLVED
| # | Item | Known | Remaining |
|---|------|-------|-----------|
| G5 | Hole geometric feasibility | Span = 4,000 mm, offsets = 500 mm fixed. Baseline: 10 holes × 300 mm → ~144 mm ligament (OK) | Need collision check at DV extremes. 15 × 450 mm WILL overlap. Need feasibility constraint. |
| G9 | Stress allowable basis | AISI 1005 yield ~285 MPa. 130 MPa → SF ≈ 2.2 | Need confirmation that 130 MPa limit still applies to updated model. |
### ❓ STILL OPEN (from Gen 001)
| # | Item | Why It Matters | Priority |
|---|------|---------------|----------|
| G3 | Displacement measurement location | Which node(s)? Which DOF? Magnitude or component? | High |
| G6 | Result sensors in Beam_sim1.sim | Determines extractor approach | Medium |
| G7 | NX parametric rebuild reliability | Untested across DV range | Medium |
### 🆕 NEW GAPS (from Gen 002)
| # | Item | Why It Matters | Priority |
|---|------|---------------|----------|
| G10 | Baseline displacement re-verification | 22 mm was from old model state (974 kg). True model is 11.33 kg — displacement likely different. | **High** |
| G11 | Baseline stress value | Never measured. Essential for optimization setup. | **High** |
| G12 | `beam_half_height` starting value | Expression exists but value not captured from KBS screenshots | Medium |
| G13 | `beam_half_width` starting value | Expression exists but value not captured from KBS screenshots | Medium |
| G14 | Hole diameter expression name | Need exact NX expression name (not just the value 300) | Medium |
| G15 | `p6` (hole_span) as potential DV | Antoine suggested it could be optimized. Decision needed. | Medium |
## Open Tasks
1.**Run baseline SOL 101** — get fresh displacement and stress values (G10, G11)
2.**NX model introspection** — extract all expression names/values, check sensors (G6, G12, G13, G14)
3.**Corner-case testing** — verify NX rebuild at DV extremes (G7)