feat: Add automatic solution monitor disabling for multi-solution workflows
Problem: When running optimization studies with multiple solutions (e.g., static + modal), NX opens solution monitor windows for each trial. These windows superpose and cause usability issues during long optimization runs. Solution: - Automatically disable solution monitor when solving all solutions (solution_name=None) - Loop through all solutions and set "solution monitor" property to False - Implemented in solve_simulation.py before solve execution (lines 271-295) - Includes error handling with graceful fallback Benefits: - No monitor window pile-up during optimization studies - Better performance (no GUI overhead) - No user configuration required - works automatically - Based on user-recorded journal (journal_monitor_window_off.py) Documentation: - Updated docs/NX_MULTI_SOLUTION_PROTOCOL.md with solution monitor control section - Added implementation details and when the feature activates - Cross-referenced user's recorded journal Implementation: optimization_engine/solve_simulation.py Documentation: docs/NX_MULTI_SOLUTION_PROTOCOL.md Reference: nx_journals/user_generated_journals/journal_monitor_window_off.py
This commit is contained in:
@@ -142,11 +142,65 @@ After implementing the fix, verify:
|
||||
|
||||
---
|
||||
|
||||
## Solution Monitor Window Control (November 24, 2025)
|
||||
|
||||
### Problem: Monitor Window Pile-Up
|
||||
|
||||
When running optimization studies with multiple trials, NX opens solution monitor windows for each trial. These windows:
|
||||
- Superpose on top of each other
|
||||
- Cannot be easily closed programmatically
|
||||
- Cause usability issues during long optimization runs
|
||||
- Slow down the optimization process
|
||||
|
||||
### Solution: Automatic Monitor Disabling
|
||||
|
||||
The solution monitor is now automatically disabled when solving multiple solutions (when `solution_name=None`).
|
||||
|
||||
**Implementation**: `optimization_engine/solve_simulation.py` lines 271-295
|
||||
|
||||
```python
|
||||
# CRITICAL: Disable solution monitor when solving multiple solutions
|
||||
# This prevents NX from opening multiple monitor windows which superpose and cause usability issues
|
||||
if not solution_name:
|
||||
print("[JOURNAL] Disabling solution monitor for all solutions to prevent window pile-up...")
|
||||
try:
|
||||
# Get all solutions in the simulation
|
||||
solutions_disabled = 0
|
||||
solution_num = 1
|
||||
while True:
|
||||
try:
|
||||
solution_obj_name = f"Solution[Solution {solution_num}]"
|
||||
simSolution = simSimulation1.FindObject(solution_obj_name)
|
||||
if simSolution:
|
||||
propertyTable = simSolution.SolverOptionsPropertyTable
|
||||
propertyTable.SetBooleanPropertyValue("solution monitor", False)
|
||||
solutions_disabled += 1
|
||||
solution_num += 1
|
||||
else:
|
||||
break
|
||||
except:
|
||||
break # No more solutions
|
||||
print(f"[JOURNAL] Solution monitor disabled for {solutions_disabled} solution(s)")
|
||||
except Exception as e:
|
||||
print(f"[JOURNAL] WARNING: Could not disable solution monitor: {e}")
|
||||
print(f"[JOURNAL] Continuing with solve anyway...")
|
||||
```
|
||||
|
||||
**When this activates**:
|
||||
- Automatically when `solution_name=None` (solve all solutions mode)
|
||||
- For any study with multiple trials (typical optimization scenario)
|
||||
- No user configuration required
|
||||
|
||||
**User-recorded journal**: `nx_journals/user_generated_journals/journal_monitor_window_off.py`
|
||||
|
||||
---
|
||||
|
||||
## Related Issues Fixed
|
||||
|
||||
1. **All trials showing identical frequency**: Fixed by ensuring modal solution runs
|
||||
2. **Only one data point in dashboard**: Fixed by all trials succeeding
|
||||
3. **Parallel coordinates with NaN**: Fixed by having complete data from all solutions
|
||||
4. **Solution monitor windows piling up**: Fixed by automatically disabling monitor for multi-solution runs
|
||||
|
||||
---
|
||||
|
||||
|
||||
Reference in New Issue