Major additions:
- Training data export system for AtomizerField neural network training
- Bracket stiffness optimization study with 50+ training samples
- Intelligent NX model discovery (auto-detect solutions, expressions, mesh)
- Result extractors module for displacement, stress, frequency, mass
- User-generated NX journals for advanced workflows
- Archive structure for legacy scripts and test outputs
- Protocol documentation and dashboard launcher
🤖 Generated with [Claude Code](https://claude.com/claude-code)
Co-Authored-By: Claude <noreply@anthropic.com>
Critical bug fix for LLM mode optimization:
**Problem**:
- NXParameterUpdater.update_expressions() uses NX journal to import expressions (default use_nx_import=True)
- The NX journal directly updates the PRT file on disk and saves it
- But then run_optimization.py was calling updater.save() afterwards
- save() writes self.content (loaded at initialization) back to file
- This overwrote the NX journal changes with stale binary content!
**Result**: All optimization trials produced identical FEM results because the model was never actually updated.
**Fixes**:
1. Removed updater.save() call from model_updater closure in run_optimization.py
2. Added theSession.Parts.CloseAll() in import_expressions.py to ensure changes are flushed and file is released
3. Fixed test_phase_3_2_e2e.py variable name (best_trial_file → results_file)
**Testing**: Verified expressions persist to disk correctly with standalone test.
Next step: Address remaining issue where FEM results are still identical (likely solve journal not reloading updated PRT).