Commit Graph

4 Commits

Author SHA1 Message Date
274081d977 refactor: Engine updates and NX hooks improvements
optimization_engine:
- Updated nx_solver.py with improvements
- Enhanced solve_simulation.py
- Updated extractors/__init__.py
- Improved NX CAD hooks (expression_manager, feature_manager,
  geometry_query, model_introspection, part_manager)
- Enhanced NX CAE solver_manager hook

Documentation:
- Updated OP_01_CREATE_STUDY.md protocol
- Updated SYS_12_EXTRACTOR_LIBRARY.md

🤖 Generated with [Claude Code](https://claude.com/claude-code)

Co-Authored-By: Claude Opus 4.5 <noreply@anthropic.com>
2025-12-20 13:47:21 -05:00
Antoine
70ac34e3d3 feat: Add E11 Part Mass extractor, document pyNastran mass accuracy issue
New E11 Part Mass Extractor:
- Add nx_journals/extract_part_mass_material.py - NX journal using
  NXOpen.MeasureManager.NewMassProperties() for accurate geometry-based mass
- Add optimization_engine/extractors/extract_part_mass_material.py - Python
  wrapper that reads JSON output from journal
- Add E11 entry to extractors/catalog.json

Documentation Updates:
- SYS_12_EXTRACTOR_LIBRARY.md: Add mass accuracy warning noting pyNastran
  get_mass_breakdown() under-reports ~7% on hex-dominant meshes with
  tet/pyramid fill elements. E11 (geometry .prt) should be preferred over
  E4 (BDF) unless material is overridden at FEM level.
- 01_CHEATSHEET.md: Add mass extraction tip

V14 Config:
- Expand design variable bounds (blank_backface_angle max 4.5°,
  whiffle_triangle_closeness max 80mm, whiffle_min max 60mm)

Testing showed:
- E11 from .prt: 97.66 kg (accurate - matches NX GUI)
- E4 pyNastran get_mass_breakdown(): 90.73 kg (~7% under-reported)

🤖 Generated with [Claude Code](https://claude.com/claude-code)

Co-Authored-By: Claude Opus 4.5 <noreply@anthropic.com>
2025-12-11 22:15:36 -05:00
Antoine
c6f39bfd6c docs: Update protocol docs and method selector improvements
- SYS_12: Add extractor library updates
- SYS_15: Add method selector documentation updates
- method_selector.py: Minor improvements to method selection logic

🤖 Generated with [Claude Code](https://claude.com/claude-code)

Co-Authored-By: Claude Opus 4.5 <noreply@anthropic.com>
2025-12-07 19:10:45 -05:00
Antoine
0cb2808c44 feat: Add Phase 2 & 3 physics extractors for multi-physics optimization
Phase 2 - Structural Analysis:
- extract_principal_stress: σ1, σ2, σ3 principal stresses from OP2
- extract_strain_energy: Element and total strain energy
- extract_spc_forces: Reaction forces at boundary conditions

Phase 3 - Multi-Physics:
- extract_temperature: Nodal temperatures from thermal OP2 (SOL 153/159)
- extract_temperature_gradient: Thermal gradient approximation
- extract_heat_flux: Element heat flux from thermal analysis
- extract_modal_mass: Modal effective mass from F06 (SOL 103)
- get_first_frequency: Convenience function for first natural frequency

Documentation:
- Updated SYS_12_EXTRACTOR_LIBRARY.md with E12-E18 specifications
- Updated NX_OPEN_AUTOMATION_ROADMAP.md marking Phase 3 complete
- Added test_phase3_extractors.py for validation

All extractors follow consistent API pattern returning Dict with
success, data, and error fields for robust error handling.

🤖 Generated with [Claude Code](https://claude.com/claude-code)

Co-Authored-By: Claude Opus 4.5 <noreply@anthropic.com>
2025-12-06 13:40:14 -05:00