# System Configuration > **Critical**: These are the ONLY paths and environments to be used unless explicitly reconfigured by the user. --- ## Python Environment **Environment Name**: `atomizer` **Path**: `c:/Users/antoi/anaconda3/envs/atomizer/python.exe` **Usage**: ALL Python scripts and commands MUST use this environment. ### Examples: ```bash # Correct "c:/Users/antoi/anaconda3/envs/atomizer/python.exe" script.py # WRONG - Never use test_env "c:/Users/antoi/anaconda3/envs/test_env/python.exe" script.py ``` --- ## NX/Simcenter Installation **Active Installation**: NX 2412 **Base Path**: `C:\Program Files\Siemens\NX2412` **Key Directories**: - NX Binaries: `C:\Program Files\Siemens\NX2412\NXBIN` - Material Library: `C:\Program Files\Siemens\NX2412\UGII\materials` - Python Stubs: `C:\Program Files\Siemens\NX2412\ugopen\pythonStubs` ### Critical Files: - **run_journal.exe**: `C:\Program Files\Siemens\NX2412\NXBIN\run_journal.exe` - **Material Library**: `C:\Program Files\Siemens\NX2412\UGII\materials\physicalmateriallibrary.xml` ### PROHIBITED Paths: - ❌ `C:\Program Files\Siemens\Simcenter3D_2412` - DO NOT USE - ❌ Any path containing "Simcenter3D" - DO NOT USE **Reason**: NX2412 is the primary CAD/CAE environment. Simcenter3D_2412 is a separate installation and should not be accessed unless explicitly configured by the user. --- ## NX Journal Execution **Command Template**: ```bash "C:/Program Files/Siemens/NX2412/NXBIN/run_journal.exe" -args ``` **Example**: ```bash "C:/Program Files/Siemens/NX2412/NXBIN/run_journal.exe" "optimization_engine/import_expressions.py" -args "studies/beam/model/Beam.prt" "studies/beam/model/Beam_study_variables.exp" ``` --- ## NXOpen Python Stubs (for Intellisense) **Path**: `C:\Program Files\Siemens\NX2412\ugopen\pythonStubs` **VSCode Configuration** (`.vscode/settings.json`): ```json { "python.analysis.extraPaths": [ "C:\\Program Files\\Siemens\\NX2412\\ugopen\\pythonStubs" ], "python.analysis.typeCheckingMode": "basic" } ``` --- ## Material Library Access **Library File**: `C:\Program Files\Siemens\NX2412\UGII\materials\physicalmateriallibrary.xml` **Format**: MatML XML format **Properties Available**: - `Mass_Density__RHO__6` (kg/mm³) - `Youngs_Modulus_E__31` (Pa) - `PoissonsRatio` (dimensionless) - `Yield_Strength_32` (Pa) - `Thermal_Expansion_A__34` (1/°C) - `Thermal_Conductivity__K__35` (mW/mm/°C) - `Specific_Heat_CP__23` (mJ/kg/°C) **Common Materials**: - AISI_Steel_1005 (E=200 GPa, ρ=7872 kg/m³, ν=0.25) - AISI_Steel_4340 (E=193 GPa, ρ=7850 kg/m³, ν=0.284) - Aluminum_6061-T6 (E=69 GPa, ρ=2700 kg/m³, ν=0.33) - Titanium_Ti-6Al-4V (E=114 GPa, ρ=4430 kg/m³, ν=0.34) --- ## Nastran Solver **Solver Path**: Embedded in NX2412 installation **Input Files**: `.dat` (Nastran bulk data) **Output Files**: - `.op2` (binary results - use pyNastran) - `.f06` (text results - human readable) **Material Units in .dat files**: - Young's Modulus: Pa (Pascals) - Density: kg/mm³ - Poisson's Ratio: dimensionless --- ## Future Expansion If using a different NX or Simcenter version, the user will explicitly configure: 1. Update this file with new paths 2. Update `nx_updater.py` configuration 3. Update `.vscode/settings.json` for new stub paths **Until then**: ALWAYS use NX2412 paths as documented above. --- ## Validation Checklist Before running any NX-related operation, verify: - ✅ Python command uses `atomizer` environment - ✅ NX paths point to `NX2412` (NOT Simcenter3D_2412) - ✅ Material library accessed from `NX2412\UGII\materials` - ✅ Journal script uses `NX2412\NXBIN\run_journal.exe` --- **Last Updated**: 2025-11-17 **Maintained By**: Antoine Letarte **Critical Importance**: HIGH - Incorrect paths will cause system failures