Files
Atomizer/docs/05_API_REFERENCE/system_configuration.md
Anto01 e3bdb08a22 feat: Major update with validators, skills, dashboard, and docs reorganization
- Add validation framework (config, model, results, study validators)
- Add Claude Code skills (create-study, run-optimization, generate-report,
  troubleshoot, analyze-model)
- Add Atomizer Dashboard (React frontend + FastAPI backend)
- Reorganize docs into structured directories (00-09)
- Add neural surrogate modules and training infrastructure
- Add multi-objective optimization support

🤖 Generated with [Claude Code](https://claude.com/claude-code)

Co-Authored-By: Claude <noreply@anthropic.com>
2025-11-25 19:23:58 -05:00

3.7 KiB
Raw Permalink Blame History

System Configuration

Critical: These are the ONLY paths and environments to be used unless explicitly reconfigured by the user.


Python Environment

Environment Name: atomizer

Path: c:/Users/antoi/anaconda3/envs/atomizer/python.exe

Usage: ALL Python scripts and commands MUST use this environment.

Examples:

# Correct
"c:/Users/antoi/anaconda3/envs/atomizer/python.exe" script.py

# WRONG - Never use test_env
"c:/Users/antoi/anaconda3/envs/test_env/python.exe" script.py

NX/Simcenter Installation

Active Installation: NX 2412

Base Path: C:\Program Files\Siemens\NX2412

Key Directories:

  • NX Binaries: C:\Program Files\Siemens\NX2412\NXBIN
  • Material Library: C:\Program Files\Siemens\NX2412\UGII\materials
  • Python Stubs: C:\Program Files\Siemens\NX2412\ugopen\pythonStubs

Critical Files:

  • run_journal.exe: C:\Program Files\Siemens\NX2412\NXBIN\run_journal.exe
  • Material Library: C:\Program Files\Siemens\NX2412\UGII\materials\physicalmateriallibrary.xml

PROHIBITED Paths:

  • C:\Program Files\Siemens\Simcenter3D_2412 - DO NOT USE
  • Any path containing "Simcenter3D" - DO NOT USE

Reason: NX2412 is the primary CAD/CAE environment. Simcenter3D_2412 is a separate installation and should not be accessed unless explicitly configured by the user.


NX Journal Execution

Command Template:

"C:/Program Files/Siemens/NX2412/NXBIN/run_journal.exe" <journal_script.py> -args <arg1> <arg2>

Example:

"C:/Program Files/Siemens/NX2412/NXBIN/run_journal.exe" "optimization_engine/import_expressions.py" -args "studies/beam/model/Beam.prt" "studies/beam/model/Beam_study_variables.exp"

NXOpen Python Stubs (for Intellisense)

Path: C:\Program Files\Siemens\NX2412\ugopen\pythonStubs

VSCode Configuration (.vscode/settings.json):

{
  "python.analysis.extraPaths": [
    "C:\\Program Files\\Siemens\\NX2412\\ugopen\\pythonStubs"
  ],
  "python.analysis.typeCheckingMode": "basic"
}

Material Library Access

Library File: C:\Program Files\Siemens\NX2412\UGII\materials\physicalmateriallibrary.xml

Format: MatML XML format

Properties Available:

  • Mass_Density__RHO__6 (kg/mm³)
  • Youngs_Modulus_E__31 (Pa)
  • PoissonsRatio (dimensionless)
  • Yield_Strength_32 (Pa)
  • Thermal_Expansion_A__34 (1/°C)
  • Thermal_Conductivity__K__35 (mW/mm/°C)
  • Specific_Heat_CP__23 (mJ/kg/°C)

Common Materials:

  • AISI_Steel_1005 (E=200 GPa, ρ=7872 kg/m³, ν=0.25)
  • AISI_Steel_4340 (E=193 GPa, ρ=7850 kg/m³, ν=0.284)
  • Aluminum_6061-T6 (E=69 GPa, ρ=2700 kg/m³, ν=0.33)
  • Titanium_Ti-6Al-4V (E=114 GPa, ρ=4430 kg/m³, ν=0.34)

Nastran Solver

Solver Path: Embedded in NX2412 installation

Input Files: .dat (Nastran bulk data)

Output Files:

  • .op2 (binary results - use pyNastran)
  • .f06 (text results - human readable)

Material Units in .dat files:

  • Young's Modulus: Pa (Pascals)
  • Density: kg/mm³
  • Poisson's Ratio: dimensionless

Future Expansion

If using a different NX or Simcenter version, the user will explicitly configure:

  1. Update this file with new paths
  2. Update nx_updater.py configuration
  3. Update .vscode/settings.json for new stub paths

Until then: ALWAYS use NX2412 paths as documented above.


Validation Checklist

Before running any NX-related operation, verify:

  • Python command uses atomizer environment
  • NX paths point to NX2412 (NOT Simcenter3D_2412)
  • Material library accessed from NX2412\UGII\materials
  • Journal script uses NX2412\NXBIN\run_journal.exe

Last Updated: 2025-11-17 Maintained By: Antoine Letarte Critical Importance: HIGH - Incorrect paths will cause system failures