Antoine 01a7d7d121 docs: Complete M1 mirror optimization campaign V11-V15
## M1 Mirror Campaign Summary
- V11-V15 optimization campaign completed (~1,400 FEA evaluations)
- Best design: V14 Trial #725 with Weighted Sum = 121.72
- V15 NSGA-II confirmed V14 TPE found optimal solution
- Campaign improved from WS=129.33 (V11) to WS=121.72 (V14): -5.9%

## Key Results
- 40° tracking: 5.99 nm (target 4.0 nm)
- 60° tracking: 13.10 nm (target 10.0 nm)
- Manufacturing: 26.28 nm (target 20.0 nm)
- Targets not achievable within current design space

## Documentation Added
- V15 STUDY_REPORT.md: Detailed NSGA-II results analysis
- M1_MIRROR_CAMPAIGN_SUMMARY.md: Full V11-V15 campaign overview
- Updated CLAUDE.md, ATOMIZER_CONTEXT.md with NXSolver patterns
- Updated 01_CHEATSHEET.md with --resume guidance
- Updated OP_01_CREATE_STUDY.md with FEARunner template

## Studies Added
- m1_mirror_adaptive_V13: TPE validation (291 trials)
- m1_mirror_adaptive_V14: TPE intensive (785 trials, BEST)
- m1_mirror_adaptive_V15: NSGA-II exploration (126 new FEA)

🤖 Generated with [Claude Code](https://claude.com/claude-code)

Co-Authored-By: Claude Opus 4.5 <noreply@anthropic.com>
2025-12-16 14:55:23 -05:00
..