- Add validation framework (config, model, results, study validators) - Add Claude Code skills (create-study, run-optimization, generate-report, troubleshoot, analyze-model) - Add Atomizer Dashboard (React frontend + FastAPI backend) - Reorganize docs into structured directories (00-09) - Add neural surrogate modules and training infrastructure - Add multi-objective optimization support 🤖 Generated with [Claude Code](https://claude.com/claude-code) Co-Authored-By: Claude <noreply@anthropic.com>
3.7 KiB
System Configuration
Critical: These are the ONLY paths and environments to be used unless explicitly reconfigured by the user.
Python Environment
Environment Name: atomizer
Path: c:/Users/antoi/anaconda3/envs/atomizer/python.exe
Usage: ALL Python scripts and commands MUST use this environment.
Examples:
# Correct
"c:/Users/antoi/anaconda3/envs/atomizer/python.exe" script.py
# WRONG - Never use test_env
"c:/Users/antoi/anaconda3/envs/test_env/python.exe" script.py
NX/Simcenter Installation
Active Installation: NX 2412
Base Path: C:\Program Files\Siemens\NX2412
Key Directories:
- NX Binaries:
C:\Program Files\Siemens\NX2412\NXBIN - Material Library:
C:\Program Files\Siemens\NX2412\UGII\materials - Python Stubs:
C:\Program Files\Siemens\NX2412\ugopen\pythonStubs
Critical Files:
- run_journal.exe:
C:\Program Files\Siemens\NX2412\NXBIN\run_journal.exe - Material Library:
C:\Program Files\Siemens\NX2412\UGII\materials\physicalmateriallibrary.xml
PROHIBITED Paths:
- ❌
C:\Program Files\Siemens\Simcenter3D_2412- DO NOT USE - ❌ Any path containing "Simcenter3D" - DO NOT USE
Reason: NX2412 is the primary CAD/CAE environment. Simcenter3D_2412 is a separate installation and should not be accessed unless explicitly configured by the user.
NX Journal Execution
Command Template:
"C:/Program Files/Siemens/NX2412/NXBIN/run_journal.exe" <journal_script.py> -args <arg1> <arg2>
Example:
"C:/Program Files/Siemens/NX2412/NXBIN/run_journal.exe" "optimization_engine/import_expressions.py" -args "studies/beam/model/Beam.prt" "studies/beam/model/Beam_study_variables.exp"
NXOpen Python Stubs (for Intellisense)
Path: C:\Program Files\Siemens\NX2412\ugopen\pythonStubs
VSCode Configuration (.vscode/settings.json):
{
"python.analysis.extraPaths": [
"C:\\Program Files\\Siemens\\NX2412\\ugopen\\pythonStubs"
],
"python.analysis.typeCheckingMode": "basic"
}
Material Library Access
Library File: C:\Program Files\Siemens\NX2412\UGII\materials\physicalmateriallibrary.xml
Format: MatML XML format
Properties Available:
Mass_Density__RHO__6(kg/mm³)Youngs_Modulus_E__31(Pa)PoissonsRatio(dimensionless)Yield_Strength_32(Pa)Thermal_Expansion_A__34(1/°C)Thermal_Conductivity__K__35(mW/mm/°C)Specific_Heat_CP__23(mJ/kg/°C)
Common Materials:
- AISI_Steel_1005 (E=200 GPa, ρ=7872 kg/m³, ν=0.25)
- AISI_Steel_4340 (E=193 GPa, ρ=7850 kg/m³, ν=0.284)
- Aluminum_6061-T6 (E=69 GPa, ρ=2700 kg/m³, ν=0.33)
- Titanium_Ti-6Al-4V (E=114 GPa, ρ=4430 kg/m³, ν=0.34)
Nastran Solver
Solver Path: Embedded in NX2412 installation
Input Files: .dat (Nastran bulk data)
Output Files:
.op2(binary results - use pyNastran).f06(text results - human readable)
Material Units in .dat files:
- Young's Modulus: Pa (Pascals)
- Density: kg/mm³
- Poisson's Ratio: dimensionless
Future Expansion
If using a different NX or Simcenter version, the user will explicitly configure:
- Update this file with new paths
- Update
nx_updater.pyconfiguration - Update
.vscode/settings.jsonfor new stub paths
Until then: ALWAYS use NX2412 paths as documented above.
Validation Checklist
Before running any NX-related operation, verify:
- ✅ Python command uses
atomizerenvironment - ✅ NX paths point to
NX2412(NOT Simcenter3D_2412) - ✅ Material library accessed from
NX2412\UGII\materials - ✅ Journal script uses
NX2412\NXBIN\run_journal.exe
Last Updated: 2025-11-17 Maintained By: Antoine Letarte Critical Importance: HIGH - Incorrect paths will cause system failures