- Output now matches WFE_from_CSV_OPD format: ,X,Y,Z,DX,DY,DZ (meters) - Suite regenerated using real M2 mesh (357 nodes, 308mm diameter) - All 14 clean test cases: PASS (0.000 nm error) - 3 noisy cases: expected FAIL due to low node count amplifying noise - Added --inject mode to use real FEA mesh geometry - Added lateral displacement test case
24 lines
503 B
JSON
24 lines
503 B
JSON
{
|
|
"input_coefficients": {
|
|
"5": 0.1,
|
|
"7": 0.05,
|
|
"11": 0.01
|
|
},
|
|
"coefficient_names": {
|
|
"5": "Astigmatism 45\u00b0",
|
|
"7": "Coma X",
|
|
"11": "Primary Spherical"
|
|
},
|
|
"n_points": 357,
|
|
"diameter_mm": 308.4492626330409,
|
|
"rms_nm_clean": 0.046725164260732095,
|
|
"rms_nm_with_noise": 0.046725164260732095,
|
|
"noise_rms_nm": 0.0,
|
|
"include_lateral": false,
|
|
"seed": 42,
|
|
"units": {
|
|
"positions": "meters",
|
|
"displacements": "meters",
|
|
"coefficients": "nanometers"
|
|
}
|
|
} |