Files
Atomizer/docs/archive/TESTING_STRESS_FIX.md
Anto01 0ce9ddf3e2 feat: Add LLM-native development roadmap and reorganize documentation
- Add DEVELOPMENT_ROADMAP.md with 7-phase plan for LLM-driven optimization
  - Phase 1: Plugin system with lifecycle hooks
  - Phase 2: Natural language configuration interface
  - Phase 3: Dynamic code generation for custom objectives
  - Phase 4: Intelligent analysis and decision support
  - Phase 5: Automated HTML/PDF reporting
  - Phase 6: NX MCP server integration
  - Phase 7: Self-improving feature registry

- Update README.md to reflect LLM-native philosophy
  - Emphasize natural language workflows
  - Link to development roadmap
  - Update architecture diagrams
  - Add future capability examples

- Reorganize documentation structure
  - Move old dev docs to docs/archive/
  - Clean up root directory
  - Preserve all working optimization engine code

This sets the foundation for transforming Atomizer into an AI-powered
engineering assistant that can autonomously configure optimizations,
generate custom analysis code, and provide intelligent recommendations.
2025-11-15 14:34:16 -05:00

2.5 KiB

Testing the Stress Extraction Fix

Issue Fixed

Previously, stress extraction was returning 0.0 MPa instead of the expected ~122.91 MPa.

Root Cause: For solid elements (CHEXA, CTETRA, CPENTA), von Mises stress is at index 9, not the last column.

Fix Applied: Modified op2_extractor_example.py to check element type and use correct index.

How to Test

1. Activate your test environment

conda activate test_env

2. Run the verification script

python examples/test_stress_fix.py

Expected Output

============================================================
STRESS EXTRACTION FIX VERIFICATION
============================================================

--- Displacement (baseline test) ---
Max displacement: 0.315xxx mm
Node ID: xxx
OK Displacement extractor working

--- Stress (FIXED - should show ~122.91 MPa) ---
Max von Mises: 122.91 MPa
Element ID: 79
Element type: chexa

SUCCESS! Stress extraction fixed!
Expected: ~122.91 MPa
Got:      122.91 MPa
============================================================

Alternative: Test All Extractors

python optimization_engine/result_extractors/extractors.py examples/bracket/bracket_sim1-solution_1.op2

If Successful, Commit the Fix

git add optimization_engine/result_extractors/op2_extractor_example.py
git commit -m "fix: Correct von Mises stress extraction for solid elements (CHEXA)

- Use index 9 for solid elements (CHEXA, CTETRA, CPENTA)
- Keep last column for shell elements (CQUAD4, CTRIA3)
- Fixes stress extraction returning 0.0 instead of actual values (122.91 MPa)"

git push origin main

Technical Details

pyNastran OP2 Data Structure for Solid Elements

  • Shape: [itime, nnodes, 10]
  • The 10 values are:
    [oxx, oyy, ozz, txy, tyz, txz, o1, o2, o3, von_mises]
     0    1    2    3    4    5    6   7   8   9
    
  • Von Mises is at index 9

Code Change

# BEFORE (WRONG):
stresses = stress_data.data[0, :, -1]  # Last column - WRONG for CHEXA!

# AFTER (CORRECT):
if table_name in ['chexa_stress', 'ctetra_stress', 'cpenta_stress']:
    # Solid elements: von Mises at index 9
    stresses = stress_data.data[0, :, 9]
else:
    # Shell elements: von Mises at last column
    stresses = stress_data.data[0, :, -1]

Files Modified