Added complete working example with all NX result files for testing
and validation of the OP2 result extractor.
Files Added (examples/bracket/):
- Bracket.prt: Part geometry with expressions
- Bracket_sim1.sim: Simulation definition (SOL 101 Linear Statics)
- Bracket_fem1.fem: Finite element mesh
- bracket_sim1-solution_1.op2: Binary results (666 KB)
- bracket_sim1-solution_1.f06: ASCII results log
- bracket_sim1-solution_1.dat: Nastran input deck
- Supporting files: .diag, .f04, .log, .html, .png
Validated Results from OP2:
✓ Max Displacement: 0.362 mm (node 91)
- Primary direction: -Z (-0.354 mm)
- Load application point
✓ Max von Mises Stress: 122.91 MPa (element 79, CHEXA)
- Material: Aluminum 6061-T6 (yield = 276 MPa)
- Safety Factor: 2.25 ✅ SAFE
- Well below yield strength
Units Handling:
- NX units: mm, mN (milli-newton), kg
- Stress in OP2: mN/mm² = kPa
- Conversion required: kPa / 1000 = MPa
- Displacement: mm (direct)
Model Properties:
- Analysis Type: SOL 101 Linear Statics
- Elements: 585 (CHEXA hexahedral)
- Load: ~1000 N in -Z direction (3 application points)
- Constraints: Fixed supports at base
- Material: Al 6061-T6
Optimization Potential:
Current design has good margins:
- Displacement: 0.36 mm (could allow up to ~1.0 mm)
- Stress: 122.91 MPa (could allow up to ~200 MPa)
→ Weight reduction opportunity while maintaining safety!
This validates:
- pyNastran OP2 extraction works correctly
- Units conversion handling (mN → N, kPa → MPa)
- Multi-objective optimization is feasible
- Example ready for testing optimization workflow
436 lines
34 KiB
Plaintext
436 lines
34 KiB
Plaintext
1
|
|
|
|
|
|
|
|
|
|
|
|
Unpublished Work. © 2024 Siemens
|
|
All Rights Reserved.
|
|
|
|
This software and related documentation are
|
|
proprietary to Siemens Industry
|
|
Software Inc.
|
|
|
|
Siemens and the Siemens logo are registered
|
|
trademarks of Siemens Trademark GmbH & Co. KG.
|
|
Simcenter is a trademark, or registered trademark
|
|
of Siemens Industry Software Inc. or its
|
|
subsidiaries in the United States and in other
|
|
countries. Simcenter NASTRAN is a registered
|
|
trademark of Siemens Industry Software Inc.
|
|
All other trademarks, registered trademarks or
|
|
service marks belong to their respective
|
|
holders.
|
|
|
|
LIMITATIONS TO U.S. GOVERNMENT RIGHTS. UNPUBLISHED
|
|
- RIGHTS RESERVED UNDER THE COPYRIGHT LAWS OF THE
|
|
UNITED STATES. This computer software and related
|
|
computer software documentation have been
|
|
developed exclusively at private expense and are
|
|
provided subject to the following rights: If this
|
|
computer software and computer software
|
|
documentation qualify as "commercial items" (as
|
|
that term is defined in FAR 2.101), their use,
|
|
duplication or disclosure by the U.S. Government
|
|
is subject to the protections and restrictions as
|
|
set forth in the Siemens commercial license for
|
|
software and/or documentation, as prescribed in
|
|
FAR 12.212 and FAR 27.405(b)(2)(i) (for civilian
|
|
agencies) and in DFARS 227.7202-1(a) and DFARS
|
|
227.7202-3(a) (for the Department of Defense), or
|
|
any successor or similar regulation, as applicable
|
|
or as amended from time to time. If this computer
|
|
software and computer documentation do not qualify
|
|
as "commercial items", then they are "restricted
|
|
computer software" and are provided with "restric-
|
|
tive rights", and their use, duplication or dis-
|
|
closure by the U.S. Government is subject to the
|
|
protections and restrictions as set forth in FAR
|
|
27.404(b) and FAR 52-227-14 (for civilian agencies
|
|
), and DFARS 227.7203-5(c) and DFARS 252.227-7014
|
|
(for the Department of Defense), or any successor
|
|
or similar regulation, as applicable or as amended
|
|
from time to time. Siemens Industry Software Inc.
|
|
5800 Granite Parkway, Suite 600, Plano, TX 75024
|
|
|
|
|
|
* * * * * * * * * * * * * * * * * * * *
|
|
* * * * * * * * * * * * * * * * * * * *
|
|
* * * *
|
|
* * * *
|
|
* * * *
|
|
* * * *
|
|
* * Simcenter Nastran 2412.5000 * *
|
|
* * * *
|
|
* * VERSION - 2412.5020 * *
|
|
* * * *
|
|
* * FEB 13, 2025 * *
|
|
* * * *
|
|
* * * *
|
|
* *Intel64 Family 6 Model 183 Stepp * *
|
|
* * * *
|
|
* *MODEL Intel(R) Core(TM) i7-14700 * *
|
|
* * * *
|
|
* * Windows 10 * *
|
|
* * * *
|
|
* * Compiled for X86-64 * *
|
|
* * * *
|
|
* * * * * * * * * * * * * * * * * * * *
|
|
* * * * * * * * * * * * * * * * * * * *
|
|
1
|
|
|
|
Welcome to Simcenter Nastran
|
|
----------------------------
|
|
|
|
|
|
This "news" information can be turned off by setting "news=no" in the runtime
|
|
configuration (RC) file. The "news" keyword can be set in the system RC file
|
|
for global, or multi-user control, and in a local file for local control.
|
|
Individual jobs can be controlled by setting news to yes or no on the command
|
|
line.
|
|
1 NOVEMBER 15, 2025 SIMCENTER NASTRAN 2/13/25 PAGE 1
|
|
|
|
0 N A S T R A N F I L E A N D S Y S T E M P A R A M E T E R E C H O
|
|
0
|
|
|
|
|
|
NASTRAN BUFFSIZE=32769 $(C:/PROGRAM FILES/SIEMENS/NX2412/NXNASTRAN/CONF/NASTRAN.
|
|
NASTRAN BUFFPOOL=23466
|
|
NASTRAN DIAGA=128 DIAGB=0 $(C:/PROGRAM FILES/SIEMENS/NX2412/NXNASTRAN/CONF/NASTR
|
|
NASTRAN SYSTEM(442)=2 $(COMMAND LINE[5])
|
|
NASTRAN REAL=8545370112 $(MEMORY LIMIT FOR MPI AND OTHER SPECIALIZED MODULES)
|
|
$*$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
|
$*
|
|
$* SIMCENTER V2412.0.0.7002 TRANSLATOR
|
|
$* FOR SIMCENTER NASTRAN VERSION 2412.0
|
|
$*
|
|
$* FEM FILE: C:\USERS\ANTOI\DOCUMENTS\ATOMASTE\ATOMIZER\TESTS\BRACKE
|
|
$* SIM FILE: C:\USERS\ANTOI\DOCUMENTS\ATOMASTE\ATOMIZER\TESTS\BRACKE
|
|
$* ANALYSIS TYPE: STRUCTURAL
|
|
$* SOLUTION NAME: SOLUTION 1
|
|
$* SOLUTION TYPE: SOL 101 LINEAR STATICS
|
|
$*
|
|
$* SOLVER INPUT FILE: BRACKET_SIM1-SOLUTION_1.DAT
|
|
$* CREATION DATE: 15-NOV-2025
|
|
$* CREATION TIME: 08:33:00
|
|
$* HOSTNAME: ANTOINETHINKPAD
|
|
$* NASTRAN LICENSE: DESKTOP BUNDLE
|
|
$*
|
|
$* UNITS: MM (MILLI-NEWTON)
|
|
$* ... LENGTH : MM
|
|
$* ... TIME : SEC
|
|
$* ... MASS : KILOGRAM (KG)
|
|
$* ... TEMPERATURE : DEG CELSIUS
|
|
$* ... FORCE : MILLI-NEWTON
|
|
$* ... THERMAL ENERGY : MN-MM (MICRO-JOULE)
|
|
$*
|
|
$* IMPORTANT NOTE:
|
|
$* THIS BANNER WAS GENERATED BY SIMCENTER AND ALTERING THIS
|
|
$* INFORMATION MAY COMPROMISE THE PRE AND POST PROCESSING OF RESULTS
|
|
$*
|
|
$*$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
|
$*
|
|
$*$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
|
$*
|
|
$* FILE MANAGEMENT
|
|
$*
|
|
$*$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
|
$*
|
|
$*
|
|
$*$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
|
$*
|
|
$* EXECUTIVE CONTROL
|
|
$*
|
|
$*$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
|
$*
|
|
1 NOVEMBER 15, 2025 SIMCENTER NASTRAN 2/13/25 PAGE 2
|
|
|
|
0 N A S T R A N E X E C U T I V E C O N T R O L E C H O
|
|
0
|
|
|
|
|
|
ID,NASTRAN,BRACKET_SIM1-SOLUTION_1
|
|
SOL 101
|
|
CEND
|
|
1 NOVEMBER 15, 2025 SIMCENTER NASTRAN 2/13/25 PAGE 3
|
|
|
|
0
|
|
0 C A S E C O N T R O L E C H O
|
|
COMMAND
|
|
COUNT
|
|
1 $*
|
|
2 $*$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
|
3 $*
|
|
4 $* CASE CONTROL
|
|
5 $*
|
|
6 $*$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
|
7 $*
|
|
8 ECHO = NONE
|
|
9 OUTPUT
|
|
10 DISPLACEMENT(PLOT,REAL) = ALL
|
|
11 SPCFORCES(PLOT,REAL) = ALL
|
|
12 STRESS(PLOT,REAL,VONMISES,CENTER) = ALL
|
|
13 $* STEP: SUBCASE - STATICS 1
|
|
14 SUBCASE 1
|
|
15 LABEL = SUBCASE - STATICS 1
|
|
16 LOAD = 1
|
|
17 SPC = 2
|
|
18 $*
|
|
19 $*$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
|
20 $*
|
|
21 $* BULK DATA
|
|
22 $*
|
|
23 $*$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
|
24 $*
|
|
25 BEGIN BULK
|
|
0 INPUT BULK DATA ENTRY COUNT = 1898
|
|
0 TOTAL COUNT= 1874
|
|
|
|
|
|
M O D E L S U M M A R Y
|
|
|
|
NUMBER OF GRID POINTS = 585
|
|
|
|
|
|
NUMBER OF CHEXA ELEMENTS = 306
|
|
NUMBER OF CPENTA ELEMENTS = 10
|
|
|
|
*** USER INFORMATION MESSAGE 4109 (OUTPBN2)
|
|
THE LABEL IS NX2412.5 FOR FORTRAN UNIT 12
|
|
(MAXIMUM SIZE OF FORTRAN RECORDS WRITTEN = 7 WORDS.)
|
|
(NUMBER OF FORTRAN RECORDS WRITTEN = 8 RECORDS.)
|
|
(TOTAL DATA WRITTEN FOR TAPE LABEL = 17 WORDS.)
|
|
1 NOVEMBER 15, 2025 SIMCENTER NASTRAN 2/13/25 PAGE 4
|
|
|
|
0
|
|
0
|
|
|
|
|
|
*** USER INFORMATION MESSAGE 4114 (OUTPBN2)
|
|
DATA BLOCK IBULK WRITTEN ON FORTRAN UNIT 12, TRL =
|
|
101 1 0 0 0 0 0
|
|
(MAXIMUM POSSIBLE FORTRAN RECORD SIZE = 65538 WORDS.)
|
|
(MAXIMUM SIZE OF FORTRAN RECORDS WRITTEN = 20 WORDS.)
|
|
(NUMBER OF FORTRAN RECORDS WRITTEN = 9499 RECORDS.)
|
|
(TOTAL DATA WRITTEN FOR DATA BLOCK = 45551 WORDS.)
|
|
*** USER INFORMATION MESSAGE 4114 (OUTPBN2)
|
|
DATA BLOCK ICASE WRITTEN ON FORTRAN UNIT 12, TRL =
|
|
102 27 0 0 0 0 0
|
|
(MAXIMUM POSSIBLE FORTRAN RECORD SIZE = 65538 WORDS.)
|
|
(MAXIMUM SIZE OF FORTRAN RECORDS WRITTEN = 20 WORDS.)
|
|
(NUMBER OF FORTRAN RECORDS WRITTEN = 149 RECORDS.)
|
|
(TOTAL DATA WRITTEN FOR DATA BLOCK = 674 WORDS.)
|
|
*** USER INFORMATION MESSAGE 4114 (OUTPBN2)
|
|
DATA BLOCK CASECC WRITTEN ON FORTRAN UNIT 12, TRL =
|
|
103 1 0 1200 0 0 0
|
|
(MAXIMUM POSSIBLE FORTRAN RECORD SIZE = 65538 WORDS.)
|
|
(MAXIMUM SIZE OF FORTRAN RECORDS WRITTEN = 1200 WORDS.)
|
|
(NUMBER OF FORTRAN RECORDS WRITTEN = 19 RECORDS.)
|
|
(TOTAL DATA WRITTEN FOR DATA BLOCK = 1226 WORDS.)
|
|
*** USER INFORMATION MESSAGE 4114 (OUTPBN2)
|
|
DATA BLOCK PVT0 WRITTEN ON FORTRAN UNIT 12, TRL =
|
|
101 28 0 0 0 0 0
|
|
(MAXIMUM POSSIBLE FORTRAN RECORD SIZE = 65538 WORDS.)
|
|
(MAXIMUM SIZE OF FORTRAN RECORDS WRITTEN = 28 WORDS.)
|
|
(NUMBER OF FORTRAN RECORDS WRITTEN = 19 RECORDS.)
|
|
(TOTAL DATA WRITTEN FOR DATA BLOCK = 54 WORDS.)
|
|
*** USER INFORMATION MESSAGE 4114 (OUTPBN2)
|
|
DATA BLOCK GPL WRITTEN ON FORTRAN UNIT 12, TRL =
|
|
101 585 585 0 0 0 0
|
|
(MAXIMUM POSSIBLE FORTRAN RECORD SIZE = 65538 WORDS.)
|
|
(MAXIMUM SIZE OF FORTRAN RECORDS WRITTEN = 1170 WORDS.)
|
|
(NUMBER OF FORTRAN RECORDS WRITTEN = 24 RECORDS.)
|
|
(TOTAL DATA WRITTEN FOR DATA BLOCK = 1786 WORDS.)
|
|
*** USER INFORMATION MESSAGE 4114 (OUTPBN2)
|
|
DATA BLOCK GPDT WRITTEN ON FORTRAN UNIT 12, TRL =
|
|
102 585 7 0 1 0 0
|
|
(MAXIMUM POSSIBLE FORTRAN RECORD SIZE = 65538 WORDS.)
|
|
(MAXIMUM SIZE OF FORTRAN RECORDS WRITTEN = 5850 WORDS.)
|
|
(NUMBER OF FORTRAN RECORDS WRITTEN = 19 RECORDS.)
|
|
(TOTAL DATA WRITTEN FOR DATA BLOCK = 5876 WORDS.)
|
|
*** USER INFORMATION MESSAGE 4114 (OUTPBN2)
|
|
DATA BLOCK EPT WRITTEN ON FORTRAN UNIT 12, TRL =
|
|
101 0 256 0 0 0 0
|
|
(MAXIMUM POSSIBLE FORTRAN RECORD SIZE = 65538 WORDS.)
|
|
(MAXIMUM SIZE OF FORTRAN RECORDS WRITTEN = 10 WORDS.)
|
|
(NUMBER OF FORTRAN RECORDS WRITTEN = 24 RECORDS.)
|
|
(TOTAL DATA WRITTEN FOR DATA BLOCK = 43 WORDS.)
|
|
1 NOVEMBER 15, 2025 SIMCENTER NASTRAN 2/13/25 PAGE 5
|
|
|
|
0
|
|
0
|
|
|
|
|
|
*** USER INFORMATION MESSAGE 4114 (OUTPBN2)
|
|
DATA BLOCK MPT WRITTEN ON FORTRAN UNIT 12, TRL =
|
|
101 33280 0 0 0 0 0
|
|
(MAXIMUM POSSIBLE FORTRAN RECORD SIZE = 65538 WORDS.)
|
|
(MAXIMUM SIZE OF FORTRAN RECORDS WRITTEN = 15 WORDS.)
|
|
(NUMBER OF FORTRAN RECORDS WRITTEN = 29 RECORDS.)
|
|
(TOTAL DATA WRITTEN FOR DATA BLOCK = 67 WORDS.)
|
|
*** USER INFORMATION MESSAGE 4114 (OUTPBN2)
|
|
DATA BLOCK GEOM2 WRITTEN ON FORTRAN UNIT 12, TRL =
|
|
101 0 0 128 0 128 0
|
|
(MAXIMUM POSSIBLE FORTRAN RECORD SIZE = 65538 WORDS.)
|
|
(MAXIMUM SIZE OF FORTRAN RECORDS WRITTEN = 6735 WORDS.)
|
|
(NUMBER OF FORTRAN RECORDS WRITTEN = 29 RECORDS.)
|
|
(TOTAL DATA WRITTEN FOR DATA BLOCK = 6945 WORDS.)
|
|
*** USER INFORMATION MESSAGE 4114 (OUTPBN2)
|
|
DATA BLOCK GEOM3 WRITTEN ON FORTRAN UNIT 12, TRL =
|
|
102 0 0 64 0 0 0
|
|
(MAXIMUM POSSIBLE FORTRAN RECORD SIZE = 65538 WORDS.)
|
|
(MAXIMUM SIZE OF FORTRAN RECORDS WRITTEN = 24 WORDS.)
|
|
(NUMBER OF FORTRAN RECORDS WRITTEN = 24 RECORDS.)
|
|
(TOTAL DATA WRITTEN FOR DATA BLOCK = 57 WORDS.)
|
|
*** USER INFORMATION MESSAGE 4114 (OUTPBN2)
|
|
DATA BLOCK GEOM4 WRITTEN ON FORTRAN UNIT 12, TRL =
|
|
103 0 0 0 512 0 0
|
|
(MAXIMUM POSSIBLE FORTRAN RECORD SIZE = 65538 WORDS.)
|
|
(MAXIMUM SIZE OF FORTRAN RECORDS WRITTEN = 207 WORDS.)
|
|
(NUMBER OF FORTRAN RECORDS WRITTEN = 24 RECORDS.)
|
|
(TOTAL DATA WRITTEN FOR DATA BLOCK = 240 WORDS.)
|
|
*** USER INFORMATION MESSAGE 4114 (OUTPBN2)
|
|
DATA BLOCK GEOM1 WRITTEN ON FORTRAN UNIT 12, TRL =
|
|
104 0 0 8 0 0 0
|
|
(MAXIMUM POSSIBLE FORTRAN RECORD SIZE = 65538 WORDS.)
|
|
(MAXIMUM SIZE OF FORTRAN RECORDS WRITTEN = 6438 WORDS.)
|
|
(NUMBER OF FORTRAN RECORDS WRITTEN = 24 RECORDS.)
|
|
(TOTAL DATA WRITTEN FOR DATA BLOCK = 6471 WORDS.)
|
|
*** USER INFORMATION MESSAGE 4114 (OUTPBN2)
|
|
DATA BLOCK BGPDT WRITTEN ON FORTRAN UNIT 12, TRL =
|
|
105 585 0 3510 1 0 585
|
|
(MAXIMUM POSSIBLE FORTRAN RECORD SIZE = 65538 WORDS.)
|
|
(MAXIMUM SIZE OF FORTRAN RECORDS WRITTEN = 7020 WORDS.)
|
|
(NUMBER OF FORTRAN RECORDS WRITTEN = 24 RECORDS.)
|
|
(TOTAL DATA WRITTEN FOR DATA BLOCK = 8220 WORDS.)
|
|
*** USER INFORMATION MESSAGE 4114 (OUTPBN2)
|
|
DATA BLOCK DIT WRITTEN ON FORTRAN UNIT 12, TRL =
|
|
101 32768 0 0 0 0 0
|
|
(MAXIMUM POSSIBLE FORTRAN RECORD SIZE = 65538 WORDS.)
|
|
(MAXIMUM SIZE OF FORTRAN RECORDS WRITTEN = 137 WORDS.)
|
|
(NUMBER OF FORTRAN RECORDS WRITTEN = 24 RECORDS.)
|
|
(TOTAL DATA WRITTEN FOR DATA BLOCK = 170 WORDS.)
|
|
1 NOVEMBER 15, 2025 SIMCENTER NASTRAN 2/13/25 PAGE 6
|
|
|
|
0
|
|
0
|
|
|
|
|
|
*** USER INFORMATION MESSAGE 4114 (OUTPBN2)
|
|
DATA BLOCK EQEXIN WRITTEN ON FORTRAN UNIT 12, TRL =
|
|
101 585 0 0 0 0 0
|
|
(MAXIMUM POSSIBLE FORTRAN RECORD SIZE = 65538 WORDS.)
|
|
(MAXIMUM SIZE OF FORTRAN RECORDS WRITTEN = 1170 WORDS.)
|
|
(NUMBER OF FORTRAN RECORDS WRITTEN = 24 RECORDS.)
|
|
(TOTAL DATA WRITTEN FOR DATA BLOCK = 2370 WORDS.)
|
|
1 NOVEMBER 15, 2025 SIMCENTER NASTRAN 2/13/25 PAGE 7
|
|
|
|
0
|
|
*** USER INFORMATION MESSAGE 7310 (VECPRN)
|
|
ORIGIN OF SUPERELEMENT BASIC COORDINATE SYSTEM WILL BE USED AS REFERENCE LOCATION.
|
|
RESULTANTS ABOUT ORIGIN OF SUPERELEMENT BASIC COORDINATE SYSTEM IN SUPERELEMENT BASIC SYSTEM COORDINATES.
|
|
0 OLOAD RESULTANT
|
|
SUBCASE/ LOAD
|
|
DAREA ID TYPE T1 T2 T3 R1 R2 R3
|
|
0 1 FX 0.000000E+00 ---- ---- ---- 0.000000E+00 0.000000E+00
|
|
FY ---- 0.000000E+00 ---- 0.000000E+00 ---- 0.000000E+00
|
|
FZ ---- ---- -1.000000E+06 -1.000000E+08 5.134342E+00 ----
|
|
MX ---- ---- ---- 0.000000E+00 ---- ----
|
|
MY ---- ---- ---- ---- 0.000000E+00 ----
|
|
MZ ---- ---- ---- ---- ---- 0.000000E+00
|
|
TOTALS 0.000000E+00 0.000000E+00 -1.000000E+06 -1.000000E+08 5.134342E+00 0.000000E+00
|
|
*** USER INFORMATION MESSAGE - SINGULARITIES FOUND USING EIGENVALUE METHOD
|
|
*** 1602 SINGULARITIES FOUND 1602 SINGULARITIES ELIMINATED
|
|
1 NOVEMBER 15, 2025 SIMCENTER NASTRAN 2/13/25 PAGE 8
|
|
|
|
0 SUBCASE 1
|
|
*** SYSTEM INFORMATION MESSAGE 6916 (DFMSYN)
|
|
DECOMP ORDERING METHOD CHOSEN: DEFAULT, ORDERING METHOD USED: BEND
|
|
*** USER INFORMATION MESSAGE 5293 (SSG3A)
|
|
FOR DATA BLOCK KLL
|
|
LOAD SEQ. NO. EPSILON EXTERNAL WORK EPSILONS LARGER THAN 0.001 ARE FLAGGED WITH ASTERISKS
|
|
1 5.0214214E-15 1.7700232E+05
|
|
1 NOVEMBER 15, 2025 SIMCENTER NASTRAN 2/13/25 PAGE 9
|
|
|
|
0
|
|
*** USER INFORMATION MESSAGE 7310 (VECPRN)
|
|
ORIGIN OF SUPERELEMENT BASIC COORDINATE SYSTEM WILL BE USED AS REFERENCE LOCATION.
|
|
RESULTANTS ABOUT ORIGIN OF SUPERELEMENT BASIC COORDINATE SYSTEM IN SUPERELEMENT BASIC SYSTEM COORDINATES.
|
|
0 SPCFORCE RESULTANT
|
|
SUBCASE/ LOAD
|
|
DAREA ID TYPE T1 T2 T3 R1 R2 R3
|
|
0 1 FX 5.264392E-09 ---- ---- ---- -8.248000E+01 4.167906E-14
|
|
FY ---- 9.620271E-08 ---- 1.000000E+08 ---- -2.301368E-07
|
|
FZ ---- ---- 1.000000E+06 1.663200E-09 7.734565E+01 ----
|
|
MX ---- ---- ---- 0.000000E+00 ---- ----
|
|
MY ---- ---- ---- ---- 0.000000E+00 ----
|
|
MZ ---- ---- ---- ---- ---- 0.000000E+00
|
|
TOTALS 5.264392E-09 9.620271E-08 1.000000E+06 1.000000E+08 -5.134343E+00 -2.301368E-07
|
|
*** USER INFORMATION MESSAGE 4114 (OUTPBN2)
|
|
DATA BLOCK OQG1 WRITTEN ON FORTRAN UNIT 12, TRL =
|
|
101 0 4680 15 25 0 1
|
|
(MAXIMUM POSSIBLE FORTRAN RECORD SIZE = 65538 WORDS.)
|
|
(MAXIMUM SIZE OF FORTRAN RECORDS WRITTEN = 4680 WORDS.)
|
|
(NUMBER OF FORTRAN RECORDS WRITTEN = 24 RECORDS.)
|
|
(TOTAL DATA WRITTEN FOR DATA BLOCK = 4861 WORDS.)
|
|
*** USER INFORMATION MESSAGE 4114 (OUTPBN2)
|
|
DATA BLOCK BOUGV1 WRITTEN ON FORTRAN UNIT 12, TRL =
|
|
101 0 4680 15 25 0 1
|
|
(MAXIMUM POSSIBLE FORTRAN RECORD SIZE = 65538 WORDS.)
|
|
(MAXIMUM SIZE OF FORTRAN RECORDS WRITTEN = 4680 WORDS.)
|
|
(NUMBER OF FORTRAN RECORDS WRITTEN = 24 RECORDS.)
|
|
(TOTAL DATA WRITTEN FOR DATA BLOCK = 4861 WORDS.)
|
|
*** USER INFORMATION MESSAGE 4114 (OUTPBN2)
|
|
DATA BLOCK OES1 WRITTEN ON FORTRAN UNIT 12, TRL =
|
|
101 63 11 15 25 0 1
|
|
(MAXIMUM POSSIBLE FORTRAN RECORD SIZE = 65538 WORDS.)
|
|
(MAXIMUM SIZE OF FORTRAN RECORDS WRITTEN = 59058 WORDS.)
|
|
(NUMBER OF FORTRAN RECORDS WRITTEN = 34 RECORDS.)
|
|
(TOTAL DATA WRITTEN FOR DATA BLOCK = 60903 WORDS.)
|
|
1 NOVEMBER 15, 2025 SIMCENTER NASTRAN 2/13/25 PAGE 10
|
|
|
|
0
|
|
1 NOVEMBER 15, 2025 SIMCENTER NASTRAN 2/13/25 PAGE 11
|
|
|
|
0
|
|
1 NOVEMBER 15, 2025 SIMCENTER NASTRAN 2/13/25 PAGE 12
|
|
|
|
0
|
|
*** USER INFORMATION MESSAGE 4110 (OUTPBN2)
|
|
END-OF-DATA SIMULATION ON FORTRAN UNIT 12
|
|
(MAXIMUM SIZE OF FORTRAN RECORDS WRITTEN = 1 WORDS.)
|
|
(NUMBER OF FORTRAN RECORDS WRITTEN = 1 RECORDS.)
|
|
(TOTAL DATA WRITTEN FOR EOF MARKER = 1 WORDS.)
|
|
1 NOVEMBER 15, 2025 SIMCENTER NASTRAN 2/13/25 PAGE 13
|
|
|
|
0
|
|
* * * * D B D I C T P R I N T * * * * SUBDMAP = PRTSUM , DMAP STATEMENT NO. 28
|
|
|
|
|
|
|
|
0 * * * * A N A L Y S I S S U M M A R Y T A B L E * * * *
|
|
0 SEID PEID PROJ VERS APRCH SEMG SEMR SEKR SELG SELR MODES DYNRED SOLLIN PVALID SOLNL LOOPID DESIGN CYCLE SENSITIVITY
|
|
--------------------------------------------------------------------------------------------------------------------------
|
|
0 0 1 1 ' ' T T T T T F F T 0 F -1 0 F
|
|
0SEID = SUPERELEMENT ID.
|
|
PEID = PRIMARY SUPERELEMENT ID OF IMAGE SUPERELEMENT.
|
|
PROJ = PROJECT ID NUMBER.
|
|
VERS = VERSION ID.
|
|
APRCH = BLANK FOR STRUCTURAL ANALYSIS. HEAT FOR HEAT TRANSFER ANALYSIS.
|
|
SEMG = STIFFNESS AND MASS MATRIX GENERATION STEP.
|
|
SEMR = MASS MATRIX REDUCTION STEP (INCLUDES EIGENVALUE SOLUTION FOR MODES).
|
|
SEKR = STIFFNESS MATRIX REDUCTION STEP.
|
|
SELG = LOAD MATRIX GENERATION STEP.
|
|
SELR = LOAD MATRIX REDUCTION STEP.
|
|
MODES = T (TRUE) IF NORMAL MODES OR BUCKLING MODES CALCULATED.
|
|
DYNRED = T (TRUE) MEANS GENERALIZED DYNAMIC AND/OR COMPONENT MODE REDUCTION PERFORMED.
|
|
SOLLIN = T (TRUE) IF LINEAR SOLUTION EXISTS IN DATABASE.
|
|
PVALID = P-DISTRIBUTION ID OF P-VALUE FOR P-ELEMENTS
|
|
LOOPID = THE LAST LOOPID VALUE USED IN THE NONLINEAR ANALYSIS. USEFUL FOR RESTARTS.
|
|
SOLNL = T (TRUE) IF NONLINEAR SOLUTION EXISTS IN DATABASE.
|
|
DESIGN CYCLE = THE LAST DESIGN CYCLE (ONLY VALID IN OPTIMIZATION).
|
|
SENSITIVITY = SENSITIVITY MATRIX GENERATION FLAG.
|
|
1 * * * END OF JOB * * *
|
|
|
|
|