This checklist condenses the current P11 firmware/control spec for implementation tracking.

Input contract

  • Accepts controller-job.v1 only.
  • Rejects job.v1 and malformed input.
  • Runs 4-gate intake validation.
  • Rejects wrong machine_id.
  • Rejects incompatible controller_version or unsupported capability.

Execution

  • Sequential segment execution exists for future job mode.
  • Force PID tracks setpoint within agreed commissioning tolerance.
  • Force modulation uses live table encoder angle.
  • Table and spindle RPM follow commands.
  • Pause time excluded from segment polishing time.

Telemetry

  • Core channels logged at >=100 Hz.
  • Single monotonic timestamp source.
  • Commanded and actual values both present.
  • Sensor faults are detectable.
  • CSV parseable by standard tools.

State machine and safety

  • All accepted states/transitions implemented.
  • Illegal transitions logged.
  • Operator acknowledge cannot be bypassed.
  • E-stop all-stop independent of software state.
  • Interlocks implemented with documented thresholds.
  • Watchdog timeout causes pause, then abort.
  • FAULTED exits only through explicit reset.

Manual mode

  • MANUAL reachable from IDLE.
  • Live setpoint adjustment works.
  • Geometric gate blocks stale geometry.
  • Setpoint changes are timestamped events.
  • Manual-session log emitted on exit.
  • Safety behavior identical to job mode.

Data

  • /data/manual/{session_id}/ and /data/runs/{run_id}/ layouts respected.
  • status.json maintained.
  • Hashes/manifests emitted.
  • Raw telemetry preserved during commissioning.