- Restructure docs/ folder (remove numeric prefixes): - 04_USER_GUIDES -> guides/ - 05_API_REFERENCE -> api/ - 06_PHYSICS -> physics/ - 07_DEVELOPMENT -> development/ - 08_ARCHIVE -> archive/ - 09_DIAGRAMS -> diagrams/ - Replace tagline 'Talk, don't click' with 'LLM-driven optimization framework' in 9 files - Create comprehensive docs/GETTING_STARTED.md: - Prerequisites and quick setup - Project structure overview - First study tutorial (Claude or manual) - Dashboard usage guide - Neural acceleration introduction - Rewrite docs/00_INDEX.md with correct paths and modern structure - Archive obsolete files: - 01_PROTOCOLS.md -> archive/historical/01_PROTOCOLS_legacy.md - 03_GETTING_STARTED.md -> archive/historical/ - ATOMIZER_PODCAST_BRIEFING.md -> archive/marketing/ - Update timestamps to 2026-01-20 across all key files - Update .gitignore to exclude docs/generated/ - Version bump: ATOMIZER_CONTEXT v1.8 -> v2.0
145 lines
3.7 KiB
Markdown
145 lines
3.7 KiB
Markdown
# System Configuration
|
||
|
||
> **Critical**: These are the ONLY paths and environments to be used unless explicitly reconfigured by the user.
|
||
|
||
---
|
||
|
||
## Python Environment
|
||
|
||
**Environment Name**: `atomizer`
|
||
|
||
**Path**: `c:/Users/antoi/anaconda3/envs/atomizer/python.exe`
|
||
|
||
**Usage**: ALL Python scripts and commands MUST use this environment.
|
||
|
||
### Examples:
|
||
```bash
|
||
# Correct
|
||
"c:/Users/antoi/anaconda3/envs/atomizer/python.exe" script.py
|
||
|
||
# WRONG - Never use test_env
|
||
"c:/Users/antoi/anaconda3/envs/test_env/python.exe" script.py
|
||
```
|
||
|
||
---
|
||
|
||
## NX/Simcenter Installation
|
||
|
||
**Active Installation**: NX 2412
|
||
|
||
**Base Path**: `C:\Program Files\Siemens\NX2412`
|
||
|
||
**Key Directories**:
|
||
- NX Binaries: `C:\Program Files\Siemens\NX2412\NXBIN`
|
||
- Material Library: `C:\Program Files\Siemens\NX2412\UGII\materials`
|
||
- Python Stubs: `C:\Program Files\Siemens\NX2412\ugopen\pythonStubs`
|
||
|
||
### Critical Files:
|
||
- **run_journal.exe**: `C:\Program Files\Siemens\NX2412\NXBIN\run_journal.exe`
|
||
- **Material Library**: `C:\Program Files\Siemens\NX2412\UGII\materials\physicalmateriallibrary.xml`
|
||
|
||
### PROHIBITED Paths:
|
||
- ❌ `C:\Program Files\Siemens\Simcenter3D_2412` - DO NOT USE
|
||
- ❌ Any path containing "Simcenter3D" - DO NOT USE
|
||
|
||
**Reason**: NX2412 is the primary CAD/CAE environment. Simcenter3D_2412 is a separate installation and should not be accessed unless explicitly configured by the user.
|
||
|
||
---
|
||
|
||
## NX Journal Execution
|
||
|
||
**Command Template**:
|
||
```bash
|
||
"C:/Program Files/Siemens/NX2412/NXBIN/run_journal.exe" <journal_script.py> -args <arg1> <arg2>
|
||
```
|
||
|
||
**Example**:
|
||
```bash
|
||
"C:/Program Files/Siemens/NX2412/NXBIN/run_journal.exe" "optimization_engine/import_expressions.py" -args "studies/beam/model/Beam.prt" "studies/beam/model/Beam_study_variables.exp"
|
||
```
|
||
|
||
---
|
||
|
||
## NXOpen Python Stubs (for Intellisense)
|
||
|
||
**Path**: `C:\Program Files\Siemens\NX2412\ugopen\pythonStubs`
|
||
|
||
**VSCode Configuration** (`.vscode/settings.json`):
|
||
```json
|
||
{
|
||
"python.analysis.extraPaths": [
|
||
"C:\\Program Files\\Siemens\\NX2412\\ugopen\\pythonStubs"
|
||
],
|
||
"python.analysis.typeCheckingMode": "basic"
|
||
}
|
||
```
|
||
|
||
---
|
||
|
||
## Material Library Access
|
||
|
||
**Library File**: `C:\Program Files\Siemens\NX2412\UGII\materials\physicalmateriallibrary.xml`
|
||
|
||
**Format**: MatML XML format
|
||
|
||
**Properties Available**:
|
||
- `Mass_Density__RHO__6` (kg/mm³)
|
||
- `Youngs_Modulus_E__31` (Pa)
|
||
- `PoissonsRatio` (dimensionless)
|
||
- `Yield_Strength_32` (Pa)
|
||
- `Thermal_Expansion_A__34` (1/°C)
|
||
- `Thermal_Conductivity__K__35` (mW/mm/°C)
|
||
- `Specific_Heat_CP__23` (mJ/kg/°C)
|
||
|
||
**Common Materials**:
|
||
- AISI_Steel_1005 (E=200 GPa, ρ=7872 kg/m³, ν=0.25)
|
||
- AISI_Steel_4340 (E=193 GPa, ρ=7850 kg/m³, ν=0.284)
|
||
- Aluminum_6061-T6 (E=69 GPa, ρ=2700 kg/m³, ν=0.33)
|
||
- Titanium_Ti-6Al-4V (E=114 GPa, ρ=4430 kg/m³, ν=0.34)
|
||
|
||
---
|
||
|
||
## Nastran Solver
|
||
|
||
**Solver Path**: Embedded in NX2412 installation
|
||
|
||
**Input Files**: `.dat` (Nastran bulk data)
|
||
|
||
**Output Files**:
|
||
- `.op2` (binary results - use pyNastran)
|
||
- `.f06` (text results - human readable)
|
||
|
||
**Material Units in .dat files**:
|
||
- Young's Modulus: Pa (Pascals)
|
||
- Density: kg/mm³
|
||
- Poisson's Ratio: dimensionless
|
||
|
||
---
|
||
|
||
## Future Expansion
|
||
|
||
If using a different NX or Simcenter version, the user will explicitly configure:
|
||
|
||
1. Update this file with new paths
|
||
2. Update `nx_updater.py` configuration
|
||
3. Update `.vscode/settings.json` for new stub paths
|
||
|
||
**Until then**: ALWAYS use NX2412 paths as documented above.
|
||
|
||
---
|
||
|
||
## Validation Checklist
|
||
|
||
Before running any NX-related operation, verify:
|
||
|
||
- ✅ Python command uses `atomizer` environment
|
||
- ✅ NX paths point to `NX2412` (NOT Simcenter3D_2412)
|
||
- ✅ Material library accessed from `NX2412\UGII\materials`
|
||
- ✅ Journal script uses `NX2412\NXBIN\run_journal.exe`
|
||
|
||
---
|
||
|
||
**Last Updated**: 2025-11-17
|
||
**Maintained By**: Antoine Letarte
|
||
**Critical Importance**: HIGH - Incorrect paths will cause system failures
|