Bug 1 — Journal (solve_simulation.py simple workflow): Expression lookup for p173 fails silently for derived/measurement expressions, so _temp_mass.txt was never written. Added MeasureManager fallback via extract_part_mass() (already used in assembly workflow). Bug 2 — Extractor (extract_mass_from_expression.py): Journal writes 'p173=<value>' format but extractor tried float() on the whole content including 'p173='. Added key=value parsing. Defense in depth — nx_interface.py: Added stdout parsing fallback: if _temp_mass.txt still missing, parse mass from journal output captured via solver.py stdout passthrough. Files changed: - optimization_engine/nx/solve_simulation.py — MeasureManager fallback - optimization_engine/extractors/extract_mass_from_expression.py — key=value parse - optimization_engine/nx/solver.py — include stdout in result dict - projects/hydrotech-beam/studies/01_doe_landscape/nx_interface.py — stdout fallback Tags: hydrotech-beam, mass-extraction