Antoine 3d90097b2b feat: Expand V14 design space bounds based on V13 analysis
Analysis of 258 FEA trials showed best trial (#45) hitting bounds on
5 parameters. Expanded bounds to allow exploration of promising regions:

- lateral_inner_angle: max 28.5 → 30.0° (was at 99.2% of range)
- lateral_inner_pivot: min 9.0 → 7.0 mm (was at 4.6% of range)
- lateral_middle_pivot: min 18.0 → 15.0 mm (was at 7.7% of range)
- whiffle_min: min 35.0 → 30.0 mm (was at 4.0% of range)
- whiffle_outer_to_vertical: min 68.0 → 60.0° (was at 5.3% of range)
- blank_backface_angle: narrowed to 4.1-4.2° (focus on optimal region)

V14 seeds from 496 prior FEA trials (V11+V12+V13) using TPE sampler.

🤖 Generated with [Claude Code](https://claude.com/claude-code)

Co-Authored-By: Claude Opus 4.5 <noreply@anthropic.com>
2025-12-11 16:42:34 -05:00
..