Files
Polisher-Control/docs/06-event-alarm-codes-v1.md
2026-05-26 16:23:04 +00:00

1012 B

Event and Alarm Codes v1

Status: draft canonical table for implementation.

Hard-stop faults — reset required

  • ESTOP_ACTIVATED
  • FORCE_OVER_LIMIT
  • ENCODER_LOST
  • DRIVE_FAULT
  • FT_SENSOR_INVALID

Recoverable pauses / warnings

  • FORCE_UNDER_LIMIT
  • SPINDLE_RPM_DEVIATION
  • TABLE_RPM_DEVIATION
  • HOST_COMMS_TIMEOUT
  • ARM_GEOMETRY_DIVERGENCE

Refused transitions / blocked starts

  • GEOMETRY_NOT_VALIDATED
  • ARM_HANDLING_INTERLOCK
  • WRONG_ARTIFACT_TYPE
  • SCHEMA_VALIDATION_FAILED
  • WRONG_MACHINE_ID
  • CONTROLLER_VERSION_MISMATCH
  • UNSUPPORTED_CAPABILITY
  • ILLEGAL_TRANSITION

Event fields

Every event should include:

{
  "timestamp": "ISO-8601 or host monotonic mapping",
  "code": "GEOMETRY_NOT_VALIDATED",
  "severity": "info|warning|critical",
  "state": "IDLE|MANUAL|...",
  "detail": "short machine-readable or operator-readable detail"
}

Do not use free text as the only control signal. Human messages are for UI; codes are for software.